EasyManua.ls Logo

Minebea Intec PR5900 - Pendeo Process

Default Icon
382 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
When corner correction is completed, it is marked with [Correction ok].
WP-D
Max 200t d= 0.02t
Min 0.4t
0000
t
Calibration @admin
Calibration weight
Corner correction
11.000 t
correction ok
Platform 1 Save
4.7.7.4 Units
In this menu item, additional weight units for the display and the display accuracy of the
digital weighbridge load cell Pendeo
®
Truck are congured.
Descriptions and settings can be found in the [Internal weighing point] menu; see
Chapter 4.7.1.3.
Accessible via MENU - [Operating] - [System setup] - [Weighing points] - [Weighing
point x] - [Units] .
WP-D
Max -------?? d= -------??
read config failed
Weighing points @admin
Weighing point A
Weighing point B
Weighing point C
Weighing point D
Internal weighing point
Internal weighing point
xBPI scale
Pendeo Truck
Parameters Calib Units
Descriptions and settings can be found in the [Internal weighing point] menu; see
Chapter 4.7.1.3.
4.7.8 Pendeo Process
In this menu item (under Weighing points), the digital precision pressure load cell
Pendeo
®
Process is assigned to a logical weighing point and congured.
- [Interface] (serial), see Chapter 4.7.8.1.
8. Once all load cells have been loaded one time, press the [Calculate] soft key to
perform corner correction.
The total weight remains unchanged. Only the eect of the individual load cells is
corrected.
9. Press the [Save] soft key to save the corner correction.
In this case: Select [Weighing point D] with [Pendeo Truck] and press the [Units] soft
key.
4 System setup Process Controller Maxxis 5 PR 5900
EN-187 Minebea Intec

Table of Contents