PC via EW-Com @admin
Interface not assigned
Save
Not assigned
Built-in RS-232
Built-in RS-485
Option-2 RS-485-A
Option-2 RS-485-B
Inactive interfaces are grayed out.
PC via EW-Com @admin
Interface
Protocol
Baudrate
Data bits
Parity
Stop bits
EW-Com slave ID
Built-in RS-485
EW-Com V1
9600 baud
8 data bits
even parity
1 stop bit
A
Default Save
Inactive parameters are grayed out.
[Protocol]
Transmission protocol
Selection: EW-Com V1, EW-Com V2, EW-Com V3
V1 for old communication programs
V2 for recipe controller
V3 for OPC
[Baud rate]
Baud rate of the data transfer.
Selection: 300, 600, 1200, 2400, 4800, [9600], 19200, 38400, 57600, 115200 baud
Note:
The selected value must match the value of the connected device.
3. Select and conrm the desired interface.
A selection window opens.
4. Select and conrm the individual parameters.
Process Controller Maxxis 5 PR 5900 4 System setup
Minebea Intec EN-62