2 CPU MODULE INSTRUCTION
2.3 Application instruction
71
2
Special timer instruction
â– Teaching timer
â– Special function timer
Shortcut control instruction
â– Rotary table shortest direction control
Ramp signal instruction
â– Ramp signal
Pulse related instruction
â– Measuring the density of 16 bit binary/32 bit binary pulses
â– 16 bit binary/32 bit binary pulse output
â– 16 bit binary/32 bit binary pulse width modulation
Drum sequence
â– 16-bit binary data absolute method
Instruction symbol Description Reference
TTMR Page 496
Instruction symbol Description Reference
STMR The 4 points from the bit device specified by (d) operate as shown below, depending on the ON/
OFF status of the input conditions for the STMR instruction:
(d)+0: Off delay timer output
(d)+1: One shot after off timer output
(d)+2: One shot after on timer output
(d)+3: On delay and off delay timer output
Page 498
Instruction symbol Description Reference
ROTC Rotates a rotary table with (n1) divisions from the stop position to the position specified by (s)+1 in
the shortest direction.
Page 500
Instruction symbol Description Reference
RAMPF Shifts the value from the one specified by (s1) to the one specified by (s2) in (n) scans.
The current value is stored in the device specified by (d1)+0.
Page 503
Instruction symbol Description Reference
SPD Counts the pulse input from the device specified by (s1) for the duration of time specified by (s2),
and stores the count in the device specified by (d).
Page 505
DSPD Page 509
Instruction symbol Description Reference
PLSY • When an FX3 series-compatible operand is specified
This instruction outputs a pulse at a frequency specified by (s) for the number of times specified by
(n) from the output number (Y) specified by (d).
• When an FX5 series-compatible operand is specified
This instruction outputs a pulse at a frequency specified by (s) for the number of times specified by
(n), from the output number (axis number) specified by (d).
Page 513
DPLSY Page 521
Instruction symbol Description Reference
PWM Outputs the pulse of the cycle specified by (s2), for the ON time on specified by (s1), to the output
number specified by (d).
Page 529
DPWM Page 533
Instruction symbol Description Reference
ABSD Creates many output patterns corresponding to the current value of a counter. Page 538
(s)=0:1, (s)=1:10, (s)=2:100
(On time of TTMR) ï‚´ (s)
(d)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC iQ-F FX5 series and is the answer not in the manual?

Mitsubishi MELSEC iQ-F FX5 series Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC iQ-F FX5 series
CategoryController
LanguageEnglish

Related product manuals