VJ-1604  Maintenance Manual 5 Self-Diagnosis Mode
5-57 Rev.-05
(3) Uni-D / Bi-D Low
This menu updates the Uni-D/ Bi-D adjustment parameter.
Table 5-16 Uni-D / Bi-D Update Item
Table 5-15 Voltage Adjustment Item
Items Contents
240 CW Adjusts the VSD 3-L (S) at 240 cps. CW printing.
240 CCW Adjusts the VSD 3-L (S) at 240 cps. CCW printing.
320 CW Adjusts the VSD 3-L (S) at 320 cps. CW printing.
320 CCW Adjusts the VSD 3-L (S) at 320 cps. CCW printing.
Item Contents
Uni-D 240 Adjusts Uni-D at 240 cps. PG Low or High
Uni-D 320 Adjusts Uni-D at 320 cps. PG Low or High
Uni-D 240B Adjusts Uni-D at 240 cps-Banner. PG Low or High
Uni-D 320B Adjusts Uni-D at 320 cps-Banner. PG Low or High
Bi-D 240 Adjusts Bi-D at 240 cps. PG Low or High
Bi-D 320 Adjusts Bi-D at 320 cps. PG Low or High
Bi-D 240B Adjusts Bi-D at 240 cps-Banner. PG Low or High
Bi-D 320B Adjusts Bi-D at 320 cps-Banner. PG Low or High
[>] keys
[>] key
[>] key
[>] key
If 240 CW is selected
[<] key
[<] key
[<] key
[<] key
Offset range: -5V to 5V (0.1V increment)
VH3L-1 to VH3L-4
VH3S-1 to VH3S-4
[Enter]
[Enter]
[Enter]