Electrical System 136Service Manual – CS7000
Maintenance and Adjustments
Charging the Battery (Battery Model)
See User Manual
Generator Drive Belt
The generator drive belt tension is maintained by an auto-tensioner and does not require adjustment.
Troubleshooting
42 volt generator is not charging
Potential Causes
• Broken or slipping drive belt - Check the drive belt
• No power to voltage regulator terminal - Check for battery voltage (36v) to the voltage regulator connector
• Open or corroded cable connections - visually inspect cable connections
• Generator/Regulator assembly
Insufcient machine operation time (Battery Model)
Potential Causes
• Battery is not fully charged
• Loose or corroded cable connections
• Battery
Insufcient machine operation time with engine off (Hybrid models)
Potential Causes
• Battery is not fully charged
• Loose or corroded cable connections
• Battery