EasyManua.ls Logo

Nilfisk-Advance CS7000 - To Remove and Reinstall the Hopper Dump Door Actuator Assembly; Hopper Interlock Switch Replacement

Nilfisk-Advance CS7000
440 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Hopper System 276Service Manual – CS7000
To Remove and Reinstall the Hopper Dump Door Actuator Assembly
1. Open the hopper and engage the hopper prop rod.
2. Open the hopper dump door to relieve the tension on the hopper dump door actuator assembly.
3. Remove the Cotter Hair Pin, Washers
and Clevis Pin holding the Dump Door
Actuator Yoke
to the Dump Door.
Note: Lifting the Dump Door up
slightly as you remove
the Clevis Pin will make
it easier to remove the
Clevis Pin from the Dump
Door
and Dump Door
Actuator Yoke
.
Note: You don’t need to remove
the cotter hair pin,
washers and clevis pin
holding the actuator and
spring in the Dump Door
Actuator Yoke
.
4. Carefully swing the Door Dump
Actuator Assembly
down to access the
Electrical Connector.
5. Disconnect the Electrical Connector.
6. Remove the cotter hair pin, washers
and Clevis Pin holding the Dump
Door Actuator Assembly
to the frame,
then remove the Dump Door Actuator
Assembly
from the machine.
7. Reinstall the hopper dump door
actuator assembly by following the
above steps in reverse order.
Hopper Interlock Switch Replacement
TSB FC 2104-005 introduced a new mounting bracket which establishes the correct air-gap for the switch
and protects it from damage. See the TSB for complete installation instructions.
Cotter
Hair Pin
Clevis
Pin
Washer (2)
Dump Door
Actuator Yoke
Dump
Door
Dump Door
Actuator
Assembly
Clevis
Pin
Electrical
Connector

Table of Contents

Other manuals for Nilfisk-Advance CS7000

Related product manuals