Solution System 330Service Manual – CS7000
To Clean the Extended Scrub System Strainer
1. Open the recovery tank cover and
remove the debris basket.
2. Rinse any accumulated material off
of the Extended Scrub System Strainer
using normal water hose pressure.
3. Reinstall the debris basket and close
the recovery tank cover.
To Clean the High Pressure Solution Filter
1. Drain and remove the recovery tank.
Note: Placeasuitablecontainerunderneaththeltertocatchanysolutionthatmayleakfromthe
hoses.
2. Unscrew the Filter Cover and remove
the Filter Cover and screen from the
Filter Base.
3. Clean any accumulated dirt or debris
from the screen.
4. Reinstall the screen into the Filter
Base
.
5. Make sure the rubber washer is
installed correctly in the Filter Cover,
then reinstall and hand-tighten the
Filter Cover.
Extended Scrub
System Strainer
Filter
Base
Filter
Cover