General Information 21Service Manual – CS7000
• On machines equipped with an “early” rear
corner roller kit but no squeegee guard kit,
it’s recommended that you remove the left
rear Corner Roller/Bumper Assembly in order
to access a tie-down location for the tow hook.
“Later” corner guard kits have been improved
to allow use of the left Tie-down Slot for
towing without removing the left corner roller/
bumper assembly.
Diagnostic and Service Tools
In addition to a full set of metric and standard tools, the following items are required in order to successfully
and quickly perform troubleshooting and repair of Nilsk-Advance Industrial oor cleaning equipment.
• Laptop computer loaded with current version of EzParts, Adobe Reader and (preferably cellular) internet
access
• Digital volt ohmmeter (DVOM) with DC current clamp
• Hydrometer
• Battery load tester for checking 36V and 12V batteries.
• Automotive fuel pressure test gauge (used on diesel engines)
• Static control wrist strap
• Set of torque wrenches
• Hard (printed) copies of service manuals for regularly serviced machines (available at www.advance-us.
com and other Nilsk-Advance websites).
These tools are also available from Nilsk-Advance, Inc.:
• Vacuum water lift gauge, p/n 56205281
Corner Roller/
Bumper
Assembly (2)