Solution System 341Service Manual – CS7000
4. Carefully slide the Detergent Pump out of the Pump
Mount Weldment
.
5. Disconnect the Detergent Hoses and Electrical
Connectors
, then remove the Detergent Pump from the
machine.
6. Reinstall the Detergent Pump by following the above
steps in reverse order.
Specications
Component Specications
Solution Solenoid Valve 36V, Coil Resistance - 72 ohms ± 10%
EcoFlex™ Detergent Pump
Type - diaphragm dosing pump with stroke adjustment
Voltage - 12 VDC
Flow Calibration - 87 ml/min ± 3 ml/min
Water Lift - 3.5 in
Solution Control Pump
(EcoFlex™ models only)
Extended Scrub Pump
Type - diaphragm, self-priming, internal check valve
Voltage - 36 VDC, permanent magnet
Current - 3.9 Amps max.
Flow Rate - 3.3 GPM @ 2.75 Amps with 20 psi inlet
pressure
Detergent
Pump (2)
Electrical
Connectors
Pump Mount
Weldment
Detergent
Hoses