Error messages when validation fails
Error messages and solutions
When you create your external location, the system validates the location. The system
checks the following aspects:
1.
Check the remote folder syntax.
Check the validity of the hostname.
Check the possibility of connecting to the remote host.
Check if the remote destination exists.
Check the possibility of writing to the remote destination.
If one of these steps fails, an error message is generated. You can read the possible so-
lutions here.
#
Possible SolutionMessage on the User
Panel
Check whether the remote username and password are
correct.
For SMB, check the remote username syntax:
- For a remote host user: <hostname>\<username>
or <ip_address>\<username>
- For a domain user: <domainname>\<username>
For WebDAV, check the path syntax.
'The user name or pass-
word is incorrect.'