EasyManua.ls Logo

R&S FSV3000 Series - Page 765

R&S FSV3000 Series
1268 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
765User Manual 1178.8520.02 ─ 01
<ch> Alternate channel number
Return values:
<LowerChan> text value
The state of the limit check for the lower alternate or adjacent
channels.
PASSED
Limit check has passed.
FAIL
Limit check has failed.
<UpperChan> text value
The state of the limit check for the upper alternate or adjacent
channels.
PASSED
Limit check has passed.
FAIL
Limit check has failed.
Example:
INIT:IMM;*WAI;
CALC:LIM:ACP:ACH:RES?
PASSED,PASSED
Usage: Query only
CALCulate<n>:LIMit<li>:ACPower:ALTernate<ch>[:RELative]:STATe
This command turns the relative limit check for the alternate channels on and off.
You have to activate the general ACLR limit check before using this command with
CALCulate<n>:LIMit<li>:ACPower[:STATe].
Suffix:
<n>
.
irrelevant
<li> irrelevant
<ch> 1..n
Alternate channel number
Manual operation: See " Limit Check " on page 165
See " Limit Checking " on page 177
CALCulate<n>:LIMit<li>:ACPower[:STATe] <State>
This command turns the limit check for ACLR measurements on and off.
Suffix:
<n>
.
irrelevant
<li> irrelevant
Configuring and Performing Measurements

Table of Contents

Other manuals for R&S FSV3000 Series

Related product manuals