Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
783User Manual 1178.8520.02 ─ 01
See also INITiate<n>:CONTinuous on page 746.
Suffix:
<n>
.
irrelevant
<li> irrelevant
<gap> Gap (CACLR) channel number
Return values:
<LowerGap_AB>,
<UpperGap_AB>
[,<LowerGap_BC>,
<UpperGap_BC>,
<LowerGap_CD>,
<UpperGap_CD>,
<LowerGap_DE>,
<UpperGap_DE>]
Limit check results for the CACLR power in the upper and lower
gap channels for the selected gap. Results are only returned for
the available sub blocks.
PASSED
Limit check has passed.
FAIL
Limit check has failed.
NONE
No results available, e.g. because limit checking was deactiva-
ted
Example:
INIT:IMM;*WAI;
CALC:LIM:ACP:GAP2:RES?
PASSED,PASSED
Usage: Query only
Manual operation: See " Limit Checking " on page 180
CALCulate<n>:MARKer<m>:FUNCtion:POWer<sb>:RESult:PHZ <State>
This command selects the way the R&S FSV/A returns results for power measure-
ments.
You can query results with CALCulate<n>:MARKer<m>:FUNCtion:POWer<sb>:
RESult?.
Suffix:
<n>
.
Window
<m> Marker
<sb> irrelevant
Parameters:
<State> ON | OFF | 1 | 0
ON | 1
Channel power density in dBm/Hz
OFF | 0
Channel power in dBm
*RST: 0
Example:
CALC:MARK:FUNC:POW:RES:PHZ ON
Output of results referred to the channel bandwidth.