Remote Control Commands
R&S
®
SMB100A
475Operating Manual 1407.0806.32 ─ 21
STEReo:DIRect "SRC=<SigSource>"
STEReo:DIRect? "SRC"
(for documentation reasons only)
Selects the signal source.
Use the SCPI command [:SOURce]:STEReo:SOURce instead.
Setting parameters:
<SigSource> 0 | 1 | 2 | 3
0
Off
1
external analog (via L and R inputs)
2
external digital
3
internal with LF generator
Example:
STEReo:DIRect "SRC=1"
The external analog L and R inputs are selected as source.
Example:
STEReo:DIRect? "SRC"
Response: "1"
STEReo:DIRect? "STATUS"
Status request as to whether the encoder or the update loader program is being execu-
ted.
Return values:
<Status> ENC
encoder program is running
UPL
update loader program is running
Example:
STEReo:DIRect? "STATUS"
Response: "ENC"
Usage: Query only
STEReo:DIRect "STORE=<DataSet#>"
Stores data in the flash memory. All RDS-specific settings are stored in data set <Data-
Set#> of the flash memory.
Setting parameters:
<DataSet#> Range: 1 to 5
Example:
STEReo:DIRect "STORE=1"
The current settings are stored in data set "1"
Direct Commands for the Stereo/RDS Coder Option R&S SMB-B5