Remote Control Commands
R&S
®
SMB100A
476Operating Manual 1407.0806.32 ─ 21
Usage: Setting only
STEReo:DIRect "TA=<State>"
STEReo:DIRect? "TA"
(for documentation reasons only)
Sets or reads the traffic announcement flag.
This flag signals whether traffic information is currently being broadcast.
Use the SCPI command [:SOURce]:STEReo:RDS:TRAFfic:ANNouncement[:
STATe] instead.
Setting parameters:
<State> 0 | 1
Example:
STEReo:DIRect "TA=1"
The traffic announcement flag is set to "1".
Example:
STEReo:DIRect? "TA"
Response: "1"
STEReo:DIRect "TP=<State>"
STEReo:DIRect? "TP"
(for documentation reasons only)
Sets or reads the traffic program flag. This flag signals whether traffic information is
generally transmitted.
Use the SCPI command [:SOURce]:STEReo:RDS:TRAFfic:ANNouncement[:
STATe] instead.
Setting parameters:
<State> 0 | 1
Example:
STEReo:DIRect "TP=1"
The traffic program flag is set to "1".
Example:
STEReo:DIRect? "TP"
Response: "1"
STEReo:DIRect "TRANS<DataNumber>=<DataStream>"
STEReo:DIRect? "TRANS<DataNumber>"
Transparent mode.
An RDS data stream of binary data is generated. If transparent data is selected, all
other RDS data is ignored.
Parameters:
<DataNumber> Max. 20 different data sequences can be defined.
Range: 0 to 13
Direct Commands for the Stereo/RDS Coder Option R&S SMB-B5