SM 109 D619
0 1 User selectable will automatically be locked out again after a
certain time, which is stored in System Switch
03. Note that if an RDS operation takes place,
RDS will not switch off until this time limit has
expired.
(1,1): At any time, an RDS system can access
the machine.
1 0 User selectable
1 1 Always enabled
System Switch 03 (SP No. 1-101-004)
No Function Comments
0
to
7
Length of time that RDS is
temporarily switched on when
bits 6 and 7 of System Switch
02 are set to "User selectable"
00 - 99 hours (BCD).
This setting is only valid if bits 6 and 7 of
System Switch 02 are set to "User selectable".
The default setting is 24 hours.
System Switch 04 (SP No. 1-101-005)
No Function Comments
0-2 Not used Do not change these settings.
3
Printing dedicated TX
parameters on Quick/Speed
Dial Lists
0: Disabled
1: Enabled
1: Each Quick/Speed dial number on the list is
printed with the dedicated TX parameters (10
bytes each).
The first 10 bytes of data are the programmed
dedicated TX parameters; 34 bytes of data are
printed (the other 24 bytes have no use for
service technicians).
4-7 Not used Do not change these settings.
System Switch 05 - Not used (Do not change the factory settings.)
System Switch 06 - Not used (Do not change the factory settings.)
System Switch 07 - Not used (Do not change the factory settings.)
System Switch 08 - Not used (Do not change the factory settings.)