2.4 SC300: IMAGE DEVELOPMENT 1
2.4.1 SC300
SC300-00
D
Charge corona output error
The feedback voltage from the charge corona unit is detected too
high 9 times.
-
Charge corona power pack defective
Charge corona harness disconnected
Poor charge corona unit connection
SC305-00
D
Charge corona wire cleaner error 1
The charge cleaner pad does not arrive at the home position:
Motor locked within 4 s after switching on, or does not lock within
30 s.
Motor locked within 10 s after reversing, or does not lock within 30
s.
-
Charge corona wire cleaner motor defective
Motor driver defective
SC306-00
C
Charge corona wire cleaner error 2
Charge corona motor is disconnected. (The current at the charge
corona motor is detected less than 83 mA.)
-
Charge corona wire cleaner motor connector is defective or
disconnected.