Other Problems
SM 6-25 D131/D132/D133
Trouble-
shooting
6.6 OTHER PROBLEMS
6.6.1 BLOWN FUSE CONDITIONS
Fuse
Rating
Symptom at Power On
115 V 210~230V
FU1 2A/125V Anti-condensation heater does not operate.
8A/250V Machine does not operate
FU101 12A/125V 5V/250V Machine does not operate
FU103 6.3A/125V 6.3A/250V "Please Wait" then halts.
FU104 6.3A/125V 6.3A/250V SC569-00
FU105 6.3A/125V 6.3A/250V Door Open” is displayed.
FU106 6.3A/125V 6.3A/250V ADF does not operate.
FU107 6.3A/125V 6.3A/250V SC569-00
FU108 6.3A/125V 6.3A/250V Finisher does not work.
FU109 6.3A/125V 6.3A/250V Door Open” is displayed.
FU110 6.3A/125V 6.3A/250V SC324-01
FU111 6.3A/125V 6.3A/250V SC530-00
FU113 2A/125V Fax unit does not operate
FU115 8A/125V Japan only
FU116 8A/125V Japan only