and
Adjustment
Cleaning Requirement
The toner pan [E] must be cleaned at every PM interval (300 K).
4.7.7 DEVELOPMENT MOTOR
1. Flywheel [A] (
x 3)
2. Waste toner pump tube [B] (
x 1, x 1)
3. Drive rod [C]
Lift the toner pump tube to disengage the drive rod, pull out the rod, and push the rubber
tube aside.
4. Development motor bracket [D] (
x 3, x 1)
5. Development motor [E] (
x 4)