PM Tables
D131/D132/D133 3-6 SM
Fusing Unit and Paper Exit
300K 450K 900K AN Exp. Note
Fusing Entrance Guide
Plate
C
Dry cloth
Fusing Exit Guide Plate C Dry cloth
Fusing Lamps I
Hot Roller R 450
Hot Roller Bearings R 450
Pressure Roller R 450
Pressure Roller Bearings R 450
Pressure Cleaning Roller R 450 Replace as a set.
Pressure Cleaning Roller
Bearings
R
450
Hot Roller Strippers R 450
Thermistors x2 R
Cleaning Web R
Cleaning Web Pressure
Roller
R
Replace roller and
bushings together.
Cleaning Web Pressure
Roller Bearings
R
900
De-Curler Rollers C Alcohol
Exit Static Discharge
Brush
I
Exit Rollers (Top, Bottom)