shooting
6.5.2 TRANSPORT, INVERTER, FEED OUT: FACE-DOWN
(1):
From the registration sensor to the fusing unit exit, jam detection is the same as
face-up feed out.
(2):
Exit unit entrance sensor ON > Duplex entrance sensor does not switch OFF at the
correct time.
(3):
Registration sensor OFF > Duplex entrance sensor does not switch OFF at the
correct time.
(4):
Duplex entrance sensor ON > Inverter exit sensor does not switch OFF at the
correct time.
(5): Inverter exit sensor ON > Paper exit sensor does not switch ON at the correct time.
(6):
Duplex entrance sensor OFF > Paper exit sensor does not switch OFF at the
correct time. (Paper remains at the duplex unit exit.)