Fusing Unit
SM 4-83 D131/D132/D133
Replacement
and
Adjustment
4.9.9 NIP BAND WIDTH ADJUSTMENT
1. After the machine is powered on with the main switch, make an A4/LT LEF copy, then stop the
machine while the paper is still in the fusing unit by switching it off.
This is easier with an OHP sheet. Use an OHP sheet if you have one available.
2. Open the front door, then turn the fusing knob to feed out the copy.
3. Measure the width of the band on the part of the image where it is particularly black. The band,
called the nip band [A], should be 9.0 ± 0.7 mm at the center.
When the fusing is incorrect (wrinkles, offset, curl), measure the nip band width.
The nip band width can be adjusted by changing the position of the springs [B] on
either end of the pressure roller.
The fusing temperature can also be adjusted with SP1105 (Fusing Temperature
Adjustment) for Normal, OHP, and Thick Paper.