MFP Options
SM 2-111 D131/D132/D133
Installation
2.19.7 FILE FORMAT CONVERTER TYPE E (D377)
Accessory Check
Check the accessories and their quantities against this list:
No. Description Q'ty
1. File Format Converter (MLB: Media Link Board) 1
Installation
1. Switch the machine off.
2. Remove the cover of Slot A (
x 2).
3. Insert the file format converter board into Slot A and fasten it with the screws.
4. Switch the machine on.
5. Set SP5836-3 to "1" to enable the print backup feature.
6. Confirm or set the following SP codes with the values in the table listed below.
SP No. Setting SP No. Setting
5-836-1 1 5-836-73 0
5-836-2 0 5-836-85 1
5-836-3 1 5-836-86 2
5-836-72 0 5-836-91 50
7. Set the following SP codes according to the customer's needs.
SP No. Setting Comment
SP5-836-94 2
Selects JPEG2000 file format for documents copied from
the document server to Palm2.
Note: Files backed up to Palm2 in J2K format cannot be
edited by other software applications.