Copy Image Adjustments: Printing/Scanning
SM 4-159 D131/D132/D133
Replacement
and
Adjustment
4.14.2 IMAGE ADJUSTMENTS: SCANNING
Before doing the following scanner adjustments, perform or check the printing
registration/side-to-side adjustment and the blank margin adjustment.
Use an S-5-S test chart to perform the following adjustments.
Registration: Platen Mode
1. Place the test chart on the exposure glass and make a copy from one of the feed stations.
2. Check the leading edge and side-to-side registration, and adjust them with the following SP
modes if necessary.
SP No. Name Initial Comment
SP4010
Scanner Leading
Edge Registration
0
A positive value shifts the image away from the
leading edge, a negative value shifts it toward
the leading edge.
SP4011
Scanner Side-to-Side
Registration
0
A positive value shifts the image toward the
right edge, a negative value shifts it toward the
left edge.