Paper Feed
D131/D132/D133 4-120 SM
4.11.17 REGISTRATION AND BY-PASS UNIT REMOVAL
1. Remove the development unit.
p.4-34
2. Remove the inner cover. (
x 4)
3. Disconnect the toner bottle holder connector [A] and counter connector [B].
4. Pull out the duplex unit about 10 cm.
Confirm that the registration roller is separated from the positioning pin.
5. Remove the right upper cover.
p.4-9
6. Rear upper cover
p.4-11
7. Disconnect the following connectors:
Relay clutch connector [C]
Guide plate solenoid connector [D]
Guide plate sensor connector [E]
By-pass tray unit connectors [F]