EasyManua.ls Logo

Ricoh D131 - Discharge Plate; Reinstallation

Ricoh D131
1536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Transfer Belt Unit
D131/D132/D133 4-68 SM
4.8.4 DISCHARGE PLATE
1. Remove the transfer belt unit
p.4-64
2. Remove the shoulder screw and spring [A] (
x1, Spring x1).
3. Rotate the discharge unit up, then lift it straight up to remove it.
4. Disconnect the three large tabs [B].
5. Remove the bracket [C] (
x 1).
6. Disconnect the 6 small seal case tabs [D].
7. Remove the discharge plate [E].
Reinstallation
1. Set the discharge plate and make sure that it is perfectly flat before re-connecting the tabs.
2. Before re-attaching the bracket [C], make sure that all the tabs are connected.