SC200: Exposure
D131/D132/D133 2-10 SM Appendix
2.3 SC200: EXPOSURE
2.3.1 SC200
SC202
D
Polygon mirror motor error 1: Timeout at ON
The polygon mirror motor unit did not enter "Ready" status within 20
sec. after the motor was turned on,
-
The polygon mirror motor PCB connector is loose, broken, or
defective
Polygon mirror motor PCB defective
Polygon mirror motor defective
IPU defective
SC203
D
Polygon mirror motor error 2: Timeout at OFF
The polygon mirror motor did not leave "Ready" within 3 sec. after the
motor was switched off. (The XSCRDY signal did not go HIGH (inactive)
within 3 sec.)
-
The polygon mirror motor PCB connector is loose, broken, or
defective
Polygon mirror motor PCB defective
Polygon mirror motor defective
IPU defective
SC204
D
Polygon mirror motor error 3: XSCRDY signal error
The polygon mirror motor "Ready" signal goes inactive (HIGH) while
images are being produced or the synchronization signal is being
output.
-
Polygon mirror motor PCB connector loose, broken, defective
Polygon mirror motor PCB defective
Polygon mirror motor defective