EasyManua.ls Logo

Ricoh D131 - Page 1034

Ricoh D131
1536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
D619 142 SM
Communication Switch 0E (SP No. 1-104-015)
No Function Comments
0-7
Minimum interval between
automatic dialing attempts
06 to FF (Hex), unit = 2 s
(e.g., 06(H) = 12 s)
This value is the minimum time that the machine
waits before it dials the next destination.
Communication Switch 0F Not used (do not change the settings.)
Communication Switch 10 (SP No. 1-104-017)
No Function Comments
0-7
Memory transmission:
Maximum number of dialing
attempts to the same
destination
01 FE (Hex) times
Communication Switch 11 Not used (do not change the settings.)
Communication Switch 12 (SP No. 1-104-019)
No Function Comments
0-7
Memory transmission: Interval
between dialing attempts to the
same destination
01 FF (Hex) minutes
Communication Switch 13Not used (do not change the settings.)