EasyManua.ls Logo

Ricoh D131 - Page 1061

Ricoh D131
1536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SM 169 D619
IP Fax Switch 03 (SP No. 1-111-004)
No. Function Comments
0
Effective field limitation for G3
standard function information
0: OFF, 1: 4byte (DIS)
Limits the effective field for standard G3
function information.
1
Switching between G3 standard
and G3 non standard
0: Enable switching
1: G3 standard only
Enables/disables switching between G3
standard and G3 non-standard.
2 Not used Do not change this setting.
3
ECM frame size selection at
transmitting
0: 256byte, 1: 64byte
Selects the ECM frame size for sending.
4
DIS detection times for echo
prevention
0: 1 time, 1: 2 times
Sets the number of times for DIS to detect
echoes.
5
CTC transmission selection
0: PPRx1
1: PPRx4
When "0" is selected, the transmission
condition is decided by error frame
numbers.
When "1" is selected, the transmission
condition is based on the ITU-T method.
6
Shift down setting at receiving
negative code
0: OFF, 1: ON
Selects whether to shift down when
negative codes are received.
7 Not used Do not change this setting.

Table of Contents

Related product manuals