EasyManua.ls Logo

Ricoh D131 - Page 475

Ricoh D131
1536 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SC100: Scanning
D131/D132/D133 2-8 SM Appendix
SC181
D
Inverter Fan Error
When the exposure lamp is triggered on, the inverter fan motor does not
rotate.
-
SIOB defective
BCU defective
Inverter fan motor defective
Harness between the inverter fan motor - SIOB is disconnected
Harness between the SIOB BCU is disconnected
Harness between the SIOB PSU is disconnected
SC182
D
Scanner Fan Error: Right Side
The fan located on the right side of the exposure unit is not rotating.
-
Check the fan connections
Fan defective
Check SBU connection
SBU defective
SC185
D
CIS transmission error
Error caused during ASIC register's automatic initialization on the CIS,
or during transmission between the CIS DF.
-
Harness between the CIS DF is disconnected
CIS defective
SC186 D
CIS LED error
LED on the CIS causes error
During initializing, the ration of the average between leading-edge
area and rear-edge is beyond the permissible level (0.7 1.43).
During scanning, the shading data peak is under 32(8bit).
Harness CN210 and CN220 on ADF are disconnected.
Otherwise, replace CIS.

Table of Contents