Loading...
SC800: Overall System
D131/D132/D133 2-72 SM Appendix
SC820 D
0008 Self-diagnostic Error: CPU: System Call Exception GW
0612 Self-diagnostic Error: CPU: ASIC Interrupt Error GW
System program defective
Controller board defective
Optional board defective
Replace controller firmware
Note: For more details about this SC code error, execute SP5990 to print
an SMC report so you can read the error code. The error code is not
displayed on the operation panel.
For more details about this SC code error, execute SP5990 to print an SMC report so you
can read the error code. The error code is not displayed on the operation panel.
SC821 D Self-diagnostics error: ASIC GW
[0B00]
ASIC register check error
A write-verify check occurred in the ASIC.
ASIC device
Controller board defective
[0B06]
ASIC detection error
The I/O ASIC for system control was not detected.
Defective ASIC
Defective North Bridge and PCII/F
Controller board defective
For more details about this SC code error, execute SP5990 to print an SMC report so you
can read the error code. The error code is not displayed on the operation panel.