SC800: Overall System
D131/D132/D133 2-74 SM Appendix
[3014]
Diagnostics command error (First machine)
Diagnostic command issued an error because Mandolin was not
detected, or there was a w/r/c error in the HDD register
Defective HDD device
Replace the HDD device.
SC823 B Self-diagnostics error: NIC
[6101]
MAC address check sum error
The result of the MAC address check sum did not match the check sum
stored in ROM.
Defective SEEP ROM
Defective I2C bus (connection)
Replace the controller board
[6104]
PHY IC error
The PHY IC on the controller was not recognized.
Defective PHY chip
Defective ASIC MII I/F
Replace the controller board
[6105]
PHY IC loop-back error
An error occurred during the loop-back test for the PHY IC on the
controller.
Defective PHY chip
Defective MAC of ASIC (SIMAC/COMIC/CELLO)
Defective I/F with the PHY board
Defective soldered connection on the PHY board
Replace the controller board