SP3000 Processing
SM Appendix 3-59 D131/D132/D133
Appendix:
Service
Program
Mode Tables
3904 Warm Up Short Mode
Controls when corona wire cleaning is done to adjust the length of time that is
necessary for startup.
D131/D132: [0 to 2/0/1]
D133: [0 to 2/2/1]
0: Charge corona wire not cleaned when the machine is turned on.
Warmup Time: 30 sec. (Short Process Control is done)
1: Charge corona wire cleaned only when the machine is turned on.
Warmup Time: 30 sec. + 40 sec. (for cleaning) = 70 sec. (Short Process
Control is done)
2: Normal startup procedure at power on:
Warmup Time: 240 sec. (Full process control is done)
Potential sensor calibrated
Drum starts to turn when fusing unit gets to the warmup temperature (not
done during Short Process Control)
Potential sensor readings are used to adjust development bias, grid
voltage, laser diode.
ID sensor calibrated (not done during Short Process Control)
TD sensor calibrated (not done during Short Process Control)
3905 Exclusion Time (90 cpm): Interval Setting
Sets the length of time for the machine to wait before executing process
control after the the machine recovers from the Off Mode
[0 to 24/2/1]