Main SP Tables-2-2
System Maintenance Section 2-343 D146/D147/D148/D149/D150
SP Mode Tables
2904
[Image Transfer Reverse Time]
No longer used due to hardware changes.
003 All *ENG [0 to 200 / 40 / 10msec/step]
2905 [Dev Rvs Time]
003
K ENG [0 to 200 / 80 / 10msec/step]
Reversing time of when Bk drum motor reversing; Stripes occurring when toner
density is high can might be solved by setting value larger.
004
Cl ENG [0 to 200 / 80 / 10msec/step]
Reversing time of when FC develop motor reversing; Stripes occurring when
toner density is high can might be solved by setting value larger.
005
ALL ENG [0 to 400000 / 4000 / 10mm/step]
Interval of rotation distance till develop unit goes in to reverse; Stripes occurring
when toner density is high can might be solved by setting value smaller.
006
K *ENG [0 to 4294967295 / 0 / 1mm/step]
Counter total value for reverse decision.
007
Cl *ENG [0 to 4294967295 / 0 / 1mm/step]
Counter total value for reverse decision.
2906
[Drum Stop Angle]
Displays drum stopping degree.
001 Color *ENG [0 to 359 / 0 / 1deg/step]
002 Bk *ENG [0 to 359 / 0 / 1deg/step]