Main SP Tables-2-2
D146/D147/D148/D149/D150 2-346 System Maintenance Section
032
ColorDevM:146mm/sec *ENG [0 or 1 / 1 / 1/step]
Sets gain of develop motor: FC
§ 0: Low
§ 1:High
2930
[Transfer:Bias Limiter]
Sets limiter voltage of image transfer output.
001 Bias *ENG [0 to 7000 / 6000 / 10-V/step]
2960
[Process Interval]
Sets waiting time for till to switch to fall action after finish imaging.
001 Additional Time *ENG [0 to 10 / 0 / 1sec/step]
2974
[Trans. Contact Fgate Timing: Y]
When a white horizontal stripe occurs on the first page leading edge within
10mm or so, the cause might be form having the image transfer bias ON. In that
case, with add 100ms a step to this SP, problem will be solved. About from
100ms or more to 500ms will be the best.
001 Fwait:Y std *ENG
[0 to 3000 / 0 / 10msec/step]
002 Fwait:Y mid *ENG
003 Fwait:Y low ENG
2980 [LubricantApplication Operation]
001
Lubricant Application Setting *ENG [0 to 300 / 100 / 10page/step]
Decides whether to apply lubricant.
002
Idle Time: BK *ENG [0 to 600 / 30 / 1sec/step]
Operating time for applying lubricant for Bk (s)