Main SP Tables-2-2
D146/D147/D148/D149/D150 2-348 System Maintenance Section
010
Ambient Temp Correction
Coeff
*ENG [-1.0 to 1.0 / 0.0 / 0.1/step]
Sets coefficient for when correcting threshold of imaging Duty control with
external temperature.
011
Execution Temp. Threshold *ENG
[20.0 to 70.0 / D146: 42.0, D147:
42.0, D148: 39.0, D149: 39.0,
D150: 39.0 / 0.1deg/step]
Sets temperature threshold for to execute restricting imaging Duty. Does not
execute when "0".
012
Cancellation Temp. Threshold *ENG [0.1 to 20.0 / 0.1 / 0.1deg/step]
Sets temperature threshold (differential value between imaging Duty restrict
execution temperature) to call off imaging Duty restriction.
013
ON/OFF Setting *ENG
[0 or 1 / 1 / 1/step]
0: Not execute
1: Execute
Sets whether to control imaging Duty.
014
Duty Control_Down-time_BW *ENG [0 to 240000 / 0 / 10msec/step]
Break time for BW mode of imaging Duty.
015
Duty Control_Down-time_FC *ENG [0 to 240000 / 0 / 10msec/step]
Break time for FC mode of imaging Duty.