Main SP Tables-3
D146/D147/D148/D149/D150 2-352 System Maintenance Section
029
History:Last 9(Rear) *ENG [0 to 99999999 / 0 / 1/step]
Displays Pro-Con execution result for 9 times before.
030
History:Last 10(Rear) *ENG [0 to 99999999 / 0 / 1/step]
Displays Pro-Con execution result for 10 times before.
*SP3-012 Display result detail
Category Code Result name Description
00 and lager 00 Not executed
Factory default setting(SP
default)
10 and lager
Result(Normal)
11 Succeed -
20 and lager
ID Sensor
21 ID Sensor Vsg adjust error
Out of range from
Vsg=4.0±x.x[V/step]
22 ID Sensor LED Adjust error Ifsg>Max
23
ID Sensor Output
error(Positive reflect)
Vsg_reg<Min(Max)
24
ID Sensor output
error(Diffusion reflect)
Vsg_dif<Min(Max)
25
ID Sensor offset Voltage
error(Positive reflect)
Voffset_reg>Max
26
ID Sensor offset Voltage
error(Diffusion reflect)
Voffset_dif>Max
45 and lager
ID Pattern detect
45 ID Pattern extract error Can not detect ID Pattern
50 Vmin_Bk/K2 error(Max) K:Vmin_Bk / CMY:K2>Max
51 Vmin_Bk/K2 error(Min) K:Vmin_Bk / CMY:K2<Min
52 K5 error(Max) K5>Max
53 K5 error(Min) K5<Min
54
K5 calculated approximate
point error
K5 calculated approximate
point <Min