Main SP Tables-3
System Maintenance Section 2-353 D146/D147/D148/D149/D150
55
Develop gamma
error(Max)
Develop gamma >Max
56
Develop gamma
error(Min)
Develop gamma <Min
57
Start developing voltage:Vk
error(Max)
Start developing
voltage:Vk>Max
58
Start developing voltage:Vk
error(Min)
Start developing
voltage:Vk<Min
59 Not enough valid data
Adhesion amount data for
develop gamma calculation
point is under 2
60 and lager
Potential adjust
61 LD won’t light P patter is not written.
62 Residual potential:Vr error Vr>Max
63
Electrified potential:Vd
adjust error
Vd can not be adjusted in
target range.
64
Exposure potential:Vpl
adjust error
Vpl can not be adjusted in
target range
90 and lager
Result(End)
90 Potential not adjust
Potential control method is
set as [0:FIX]
99 Kill
Kill by door open, power off,
error.
(Set when execute.)
§ Execute result sample (In order of YMCK from left)
§ Factory default(SP default):[00,00,00,00]
§ Starting adjust:[99,99,99,99]
§ Fail Vsg adjust(Y):[21,99,99,99]
§ Error of Develop gamma Max(C):[99,99,55,99]
§ Succeed:[11,11,11,11]