Main SP Tables-3
System Maintenance Section 2-355 D146/D147/D148/D149/D150
005
Execute: M ENG
[0 or 1 / 0 / 1/step]
[Execute]
Executes TD sensor initial setting for only (M).
006
Execute: Y ENG
[0 or 1 / 0 / 1/step]
[Execute]
Executes TD sensor initial setting for only (Y).
020
Agitatiton Time *ENG [0 to 200 / 30 / 1sec/step]
Sets developing powder stirring time for when TD sensor's setting is in initial.
021
Initial TC *ENG [1.0 to 15.0 / 7.0 / 0.1wt%/step]
Sets toner density for initial chemical.
031
Vt Target:K *ENG [0.00 to 5.00 / 2.50 / 0.01V/step]
Sets Vt target value (K) for when TD sensor's setting is in initial.
032
Vt Target:C *ENG [0.00 to 5.00 / 2.50 / 0.01V/step]
Sets Vt target value (C) for when TD sensor's setting is in initial.
033
Vt Target:M *ENG [0.00 to 5.00 / 2.50 / 0.01V/step]
Sets Vt target value (M) for when TD sensor's setting is in initial.
034
Vt Target:Y *ENG [0.00 to 5.00 / 2.50 / 0.01V/step]
Sets Vt target value (M) for when TD sensor's setting is in initial.
041
Vt Target Corr:K *ENG [0.00 to 2.55 / 0.00 / 0.01V/step]
Sets metachronic correcting amount (K) for when TD sensor's setting is in initial.
042
Vt Target Corr:C *ENG [0.00 to 2.55 / 0.00 / 0.01V/step]
Sets metachronic correcting amount (C) for when TD sensor's setting is in
initial.
043
Vt Target Corr:M *ENG [0.00 to 2.55 / 0.00 / 0.01V/step]
Sets metachronic correcting amount (M) for when TD sensor's setting is in
initial.