Main SP Tables-3
D146/D147/D148/D149/D150 2-356 System Maintenance Section
044
Vt Target Corr:Y *ENG [0.00 to 2.55 / 0.00 / 0.01V/step]
Sets metachronic correcting amount (Y) for when TD sensor's setting is in initial.
3031 [TD Sens Init OK?]
001
From Left:YMCK ENG [0 to 9999 / 0 / 1/step]
Displays execution result of TD sensor initial setting.
3050 [Force Tnr Supply :Exe]
001
Execute: ALL ENG
[0 or 1 / 0 / 1/step]
[Execute]
Forcedly supply toner (all colors)
002
Execute: Col ENG
[0 or 1 / 0 / 1/step]
[Execute]
Forcedly supply toner (only CMY)
003
Execute: K ENG
[0 or 1 / 0 / 1/step]
[Execute]
Forcedly supply toner (only K)
004
Execute: C ENG
[0 or 1 / 0 / 1/step]
[Execute]
Forcedly supply toner (only C)
005
Execute: M ENG
[0 or 1 / 0 / 1/step]
[Execute]
Forcedly supply toner (only M)
006
Execute: Y ENG
[0 or 1 / 0 / 1/step]
[Execute]
Forcedly supply toner (only Y)
3050 [Force Tnr Supply :Exe]
021 Supply Quantity:K *ENG [0.0 to 5.0 / 0.5 / 0.1wt%/step]