Main SP Tables-3
System Maintenance Section 2-357 D146/D147/D148/D149/D150
Sets the amount [wt%/step] to supply toner (K) with Force toner supply.
022
Supply Quantity:C *ENG [0.0 to 5.0 / 0.5 / 0.1wt%/step]
Sets the amount [wt%/step] to supply toner (C) with Force toner supply.
023
Supply Quantity:M *ENG [0.0 to 5.0 / 0.5 / 0.1wt%/step]
Sets the amount [wt%/step] to supply toner (M) with Force toner supply.
024
Supply Quantity:Y *ENG [0.0 to 5.0 / 0.5 / 0.1wt%/step]
Sets the amount [wt%/step] to supply toner (Y) with Force toner supply.
031
ON Time *ENG [10 to 1000 / 200 / 1msec/step]
Sets supply ON time for 1time of force toner supplying process routine.
032
OFF Time *ENG [0 to 1000 / 100 / 1msec/step]
Sets supply OFF time for 1time of force toner supplying process routine.
033
RepeatCount *ENG [0 to 255 / 8 / 1times/step]
Sets repeating times for 1time of force toner supplying process routine.
3072
[T Sensor: Check]
Executes testing mode to test TD sensor's output (Vt) without stating up the
engine.
001 Execute Check ENG
[0 or 1 / 0 / 1/step]
[Execute]
3073
[T Sensor Measurement Value:]
Displays output test value of TD sensor.
001 Vt:K *ENG
[0.00 to 5.50 / 0.00 / 0.01V/step]
002 Vt:C *ENG
003 Vt:M *ENG
004 Vt:Y *ENG