Main SP Tables-3
D146/D147/D148/D149/D150 2-376 System Maintenance Section
Sets upper/lower limit threshold (K/C/M/Y) of RTP deposit amount.
031 Corr Thresh:K *ENG
[0.000 to 0.100 / 0.005 /
0.001mg/cm2/step]
032 Corr Thresh:C *ENG
[0.000 to 0.100 / 0.010 /
0.001mg/cm2/step]
033 Corr Thresh:M *ENG
034 Corr Thresh:Y *ENG
3233 [RTP Vtref Corr :Disp/Set]
041
Vtavg Weight Coeff (H) *ENG [0 to 100 / 30 / 1%/step]
Sets the weight of Vtavg and Vtref used for Vtref Correction Standard Value
when Paper Interval Adhesion Amount exceeds Adhesion Amount Threshold
(Upper Limit).
051
Vtavg Weight Coeff (M) *ENG [0 to 100 / 0 / 1%/step]
Sets the weight of Vtavg and Vtref used for Vtref Correction Standard Value
when Paper Interval Adhesion Amount exceeds Adhesion Amount Threshold
(Lower Limit).
061
Vtavg Weight Coeff (L) *ENG [0 to 100 / 5 / 1%/step]
Sets the weight of Vtavg and Vtref used for Vtref Correction Standard Value
when Paper Interval Adhesion Amount exceeds Adhesion Amount Threshold
(Lower Limit).
3234 [Vtref Corr :Disp/Set]
001
ON/OFF
*ENG
[0 or 1 / 1 / 1/step]
0: OFF
1: ON
Controls ON/OFF Vtref correction of electric potential control.
3234
[Vtref Corr :Disp/Set]
Set when controlling to keep toner density low with electric potential based on
develop gamma.
Means Vtref correction (+) side correction amount.
011 Corr Amt(+):K *ENG [0.00 to 1.00 / 0.00 / 0.01V/step]