Input Check Table
D146/D147/D148/D149/D150 3-6 System Maintenance Section
030
PTR Contact Sensor ENG
[0 or 1 / 0 / 1/step]
0: Abutting
1: Alienate
Detects image transfer belt and paper transfer rollers distance.
(0: Abutting, 1: Alienate)
031
New ITB Unit Detection ENG [0 or 1 / 0 / 1/step]
Not available with C1
032
Toner Collection Full Sensor ENG
[0 or 1 / 0 / 1/step]
0: Not full
1: full
Detects full of waste toner bottle.
(0: Not full, 1: full)
033
Toner Collection Bottle Set
Sensor
ENG
[0 or 1 / 0 / 1/step]
0: set
1: not set
Detects that waste toner bottle is set to main unit.
(0: set, 1:not set)
034
Toner End Sensor:Y ENG
[0 or 1 / 0 / 1/step]
0: End
1: Not End
Detects remaining toner amount.
*Power with SP5-804-173 before checking.
(0: End, 1: Not End)
035
Toner End Sensor:M ENG
[0 or 1 / 0 / 1/step]
0: End
1: Not End
Detects remaining toner amount.
*Power with SP5-804-173 before checking.
(0: End, 1: Not End)
036 Toner End Sensor:C ENG
[0 or 1 / 0 / 1/step]
0: End
1: Not End