Input Check Table
System Maintenance Section 3-7 D146/D147/D148/D149/D150
Check
Detects remaining toner amount.
*Power with SP5-804-173 before checking.
(0: End, 1: Not End)
037
Toner End Sensor:K ENG
[0 or 1 / 0 / 1/step]
0: End
1: Not End
Detects remaining toner amount.
*Power with SP5-804-172 before checking.
(0: End, 1: Not End)
038
Fusing:Area Detection ENG
[0 to 15 / 0 / 1/step]
0111:200V system
1011:100V System
Detects region of fusing unit.
(0111: 200V system, 1011: 100V System)
039
Fusing:New Unit Detection ENG
[0 or 1 / 0 / 1/step]
0: New
1: Old
Detects New/Old of fusing unit.
(0: New, 1: Old)
040
Fusing Temp Detect ENG
[0 or 1 / 0 / 1/step]
0: Normal
1: High temperature
Detects whether high temperature is detected from fusing unit.
(0: Normal, 1: High temperature)
041
Fusing Temp Detect 2 ENG
[0 or 1 / 0 / 1/step]
0: Normal
1: High temperature
Detects whether high temperature is detected from fusing unit.
(0: Normal, 1: High temperature)