Input Check Table
D146/D147/D148/D149/D150 3-8 System Maintenance Section
042
NC Sensor Temp Detection: 1 ENG
[0 or 1 / 0 / 1/step]
0: Normal
1: High temperature
Detects whether high temperature is detected from fusing unit.
(0: Normal, 1: High temperature)
045
Drum Phase Sensor: K ENG [0 or 1 / 0 / 1/step]
Not available with C1
046
Drum Phase Sensor: FC ENG [0 or 1 / 0 / 1/step]
Not available with C1
047
Nip Pres. Release Home
Position Sensor
ENG
[0 or 1 / 0 / 1/step]
0: Not pressured
1: pressured
Detects state of fusing nip pressure.
(0: Not pressured, 1: pressured)
048
Fusing Fan: Lock ENG
[0 or 1 / 0 / 1/step]
0: Running
1: Stopped, or locked
Detects locking of fusing exhaust heat fan.
(0: Running, 1: Stopped, or locked)
049
Dev Fan: Right: Lock ENG
[0 or 1 / 0 / 1/step]
0: Running
1: Stopped, or locked
Detects locking of developer air intake fan (right).
(0: Running, 1: Stopped, or locked)
050
Dev Fan: Left: Lock ENG
[0 or 1 / 0 / 1/step]
0: Running
1: Stopped, or locked
Detects locking of developer air intake fan (left).
(0: Running, 1: Stopped, or locked)