Output Check Table
System Maintenance Section 3-47 D146/D147/D148/D149/D150
Check
015
Pull-Out Motor Forward ENG
[0 or 1 / 0 / 1/step]
0:Off
1:On
Forwardly rotates ADF pull out motor.
016
Middle Motor Forward ENG
[0 or 1 / 0 / 1/step]
0:Off
1:On
Forwardly rotates ADF middle motor.
6124 [OUTPUT Check: 2K/3K FIN]
001
Entrance Transport Motor ENG [0 or 1 / 0 / 1/step]
Drives specified motor for a certain period of time to test operation.
002
Horizontal Transport Motor ENG [0 or 1 / 0 / 1/step]
Drives specified motor for a certain period of time to test operation.
003
Pre-Stack Transport Motor ENG [0 or 1 / 0 / 1/step]
Drives specified motor for a certain period of time to test operation.
004
ITB Transport Motor ENG [0 or 1 / 0 / 1/step]
Drives specified motor for a certain period of time to test operation.
005
Paper Exit Motor ENG [0 or 1 / 0 / 1/step]
Drives specified motor for a certain period of time to test operation.
006
Upper Junction Solenoid ENG [0 or 1 / 0 / 1/step]
Turns NO/OFF specified solenoid for validation.
007
TE Stack Plate Motor ENG [0 or 1 / 0 / 1/step]
Drives specified motor for a certain period of time to test operation.
008
Paper Exit Open/Close Guide
Plate Motor
ENG [0 or 1 / 0 / 1/step]
Drives specified motor for a certain period of time to test operation.