Output Check Table
System Maintenance Section 3-51 D146/D147/D148/D149/D150
Check
015
Punch Registration Moving
Motor
ENG [0 or 1 / 0 / 1/step]
6162
[FIN (1K FIN) OUTPUT Check]
Continuously runs specified motor for operation test.
001 Entrance Transport Motor ENG [0 or 1 / 0 / 1/step]
002 Proof Transport Motor ENG [0 or 1 / 0 / 1/step]
003
Paper Feed/Positioning &
Move Roller Motor
ENG [0 or 1 / 0 / 1/step]
6162
[FIN (1K FIN) OUTPUT Check]
Drives specified motor for a certain period of time to test operation.
004 Junction Solenoid ENG [0 or 1 / 0 / 1/step]
005 Shift Motor ENG [0 or 1 / 0 / 1/step]
006 Jogger Motor ENG [0 or 1 / 0 / 1/step]
007
Exit Guide Plate Open/Close
Motor
ENG [0 or 1 / 0 / 1/step]
008 Feed-out Motor ENG [0 or 1 / 0 / 1/step]
009 Tray Lift Motor ENG [0 or 1 / 0 / 1/step]
011 Positioning Roller Motor ENG [0 or 1 / 0 / 1/step]
012 Stapler Shift Motor ENG [0 or 1 / 0 / 1/step]
013 Stapler Motor ENG [0 or 1 / 0 / 1/step]
014 Punch Motor ENG [0 or 1 / 0 / 1/step]
015 Punch Move Motor ENG [0 or 1 / 0 / 1/step]
016
S-to-S Registration Detection
Move Motor
ENG [0 or 1 / 0 / 1/step]
017 Stack Transport Motor: Upper ENG [0 or 1 / 0 / 1/step]
018
Stck Trns Uppr Prss
Rls/Stndrd Fence Rtrct M
ENG [0 or 1 / 0 / 1/step]