SM 55 D163
Code Meaning Suggested Cause/Action
0-85 The line was disconnected
due to abnormal signaling in
V.34 control channel restart.
The signal did not stop within 10 s.
Turn off the main power switch, then turn it
back on.
If the same error is frequent, replace the
FCU.
0-86 The line was disconnected
because the other terminal
requested a data rate using
MPh that was not available in
the currently selected symbol
rate.
The other terminal was incompatible.
Ask the other party to contact the
manufacturer.
0-87 The control channel started
after an unsuccessful primary
channel.
The receiving terminal restarted the control
channel because data reception in the
primary channel was not successful.
This does not result in an error
communication.
0-88 The line was disconnected
because PPR was
transmitted/received 9
(default) times within the
same ECM frame.
Try using a lower data rate at the start.
Try adjusting the cable equalizer setting.
2-11 Only one V.21 connection flag
was received
Replace the FCU.
2-12 Modem clock irregularity Replace the FCU.
2-13 Modem initialization error Turn off the machine, then turn it back on.
Update the modem ROM.
Replace the FCU.
2-22 Counter overflow error of
JBIG chip
If error occurs frequently, change the settings
for resolution, paper size, compression type.
2-23 JBIG compression or
reconstruction error
Turn off the machine, then turn it back on.
2-24 JBIG ASIC error Turn off the machine, then turn it back on.