SM 133 D163
Communication Switch 0E (SP No. 1-104-015)
No Function Comments
0-7
Minimum interval between
automatic dialing attempts
06 to FF (Hex), unit = 2 s
(e.g., 06(H) = 12 s)
This value is the minimum time that the machine
waits before it dials the next destination.
Communication Switch 0F – Not used (do not change the settings.)
Communication Switch 10 (SP No. 1-104-017)
No Function Comments
0-7
Memory transmission:
Maximum number of dialing
attempts to the same
destination
01 – FE (Hex) times
Communication Switch 11 – Not used (do not change the settings.)
Communication Switch 12 (SP No. 1-104-019)
No Function Comments
0-7
Memory transmission: Interval
between dialing attempts to the
same destination
01 – FF (Hex) minutes
Communication Switch 13 – Not used (do not change the settings.)