Main SP Tables-1
D146/D147/D148/D149/D150 2-88 System Maintenance Section
1162 [Shading Position Temp: 12inch: 1]
001
Shading Position Temp:
12inch: 1
ENG
[0 to 250 / D146:155, D147:155,
D148:170, D149:170, D150:170 /
1deg/step]
Do not change. No 1 position (small shade) Transitions temperature of 12inch
002
Shading Position Temp:
12inch: 2
ENG
[0 to 250 / D146:165, D147:165,
D148:185, D149:185, D150:185 /
1deg/step]
Do not change. No 2 position (middle shade) Transitions temperature of 12inch
003
Shading Position Temp:
12inch: 3
ENG
[0 to 250 / D146:175, D147:175,
D148:195, D149:195, D150:195 /
1deg/step]
Do not change. No 3 position (large shade) Transitions temperature of 12inch
004
Shading Position Temp: A3: 1 ENG
[0 to 250 / D146:155, D147:155,
D148:170, D149:170, D150:170 /
1deg/step]
Do not change. No 1 position (small shade) Transitions temperature of A3
005
Shading Position Temp: A3: 2 ENG
[0 to 250 / D146:165, D147:165,
D148:185, D149:185, D150:185 /
1deg/step]
Do not change. No 2 position (middle shade) Transitions temperature of A3
006
Shading Position Temp: A3: 3 ENG
[0 to 250 / D146:175, D147:175,
D148:195, D149:195, D150:195 /
1deg/step]
Do not change. No 3 position (large shade) Transitions temperature of A3
007
Shading Position Temp: DLT:
1
ENG
[0 to 250 / D146:150, D147:150,
D148:130, D149:130, D150:130 /
1deg/step]
Do not change. No 1 position (small shade) Transitions temperature of DLT