Main SP Tables-1
System Maintenance Section 2-87 D146/D147/D148/D149/D150
012
Feed Permit
Temp.:delta:Press
ENG [0 to 200 / 100 / 1deg/step]
013 Feed Permit Rotation Time ENG [0 to 100 / 0 / 1deg/step]
021 After Job End Temp.:Center ENG [0 to 200 / 5 / 1sec/step]
022 After Job End Temp.:End ENG [0 to 200 / 5 / 1sec/step]
023 After Job End Time ENG [0 to 100 / 0 / 1sec/step]
1157
[Overshoot Prevent Control]
Do not change. Over shoot prevent control.
001
Decision Time *ENG [0 to 100 / 5 / 1sec/step]
Off sleep shift time
002
Decision Temp. *ENG
[0 to 250 / D146:185, D147:185,
D148:195, D149:200, D150:200 /
1deg/step]
Judge temperature
003
- *ENG [0 to 300 / 15 / 1sec/step]
Off sleep shift time
1161 [Shading Plate Control]
001
Judgment Temp A ENG [0 to 250 / 250 / 1deg/step]
Do not change. Temperature threshold of initial position judge
002
Judgment Temp B ENG [0 to 250 / 250 / 1deg/step]
Do not change. Temperature threshold of initial position judge
003
Position Transition Time ENG [0 to 10000 / 1000 / 1msec/step]
Do not change. Time from sensor temperature goes over threshold to position
shift fixed.
004
After Transition Time Out ENG [0 to 20000 / 0 / 1msec/step]
Do not change. Time from after position shifted to next position shift judge.